Maximum working temperature & Pressure is 180 degreeC and 10 barguage respectively.
Hydrostic test is done at 40 barguage. For 30 minute.
4 changeable and 4 rotary knifes inside pressure vessel driven by 3 phases 20 HP induction motor.
Steam is produced by electric heating jacket outside pressure vessel, heating rate is adjustable. By digital temperature controller and is limited at 180 degreeC for safety reason.